 Ray-Bar Engineering Corporation  X-Ray Protective Lead Glass For Radiation Shielding  3-Part CSI specifications

X-Ray Protective Lead Glass For Radiation Shielding

Specialty Ray-Bar X-Ray/Radiation Protective Lead Glass is utilized when a clear view and radiation shielding is of absolute priority in diagnostic, therapy, isotopic or nuclear radiation sources - used for medical treatment, imaging, testing, inspection, experimentation or energy production. Ray-Bar 1/4" X-Ray Protective Lead Glass meets Federal Specification DD-G-451. Ray-Bar X-Ray Protective Lead Glass meets National Council of Radiation Protection (NCRP) Report No. 49 criteria and standards. All calculations for shielding requirements should be determined by a qualified health radiation physicist currently recognized by the state in which the project occurs. Please see 'Diagnostic Radiation Shielding Considerations' for more information.

Technical Data Of Ray-Bar X-Ray Protective Lead Glass

Thickness:
Lead Equiv.(mm) nominal:
Lead Equiv.(in) nominal:
Lbs.lead equiv./ft' (min):
Weight - Lbs. / ft2:
Thickness Tolerance (in):
Refractive Index:
Light Transmission:
Strain Point (°C):
Softening Temperature (°C) :
  1/4" +
2.0/2.2
.078
5.0
6.1+
+.050
1.76
85%
523°
673°

Ray-Bar X-Ray Protective Lead Glass meets Federal Specification DD-G-451. X-Ray Protective Lead Glass is also available in lead equivalencies of 2.4mm, 3.2mm and 3.7mm. Ray-Bar also provides lead glass blocks up to 4" thick for high energy isotope or gamma radiation shielding. Please contact us for special requirements and special designs.

STOCK SIZES 
(Typically available 1-Day/Next Day)
    8" x 8"        24" x 24"     40" x 40"
    8" x 10 "     24" x 30"     40" x 48"
    10" x 10"    24" x 36"     40" x 60"
    10" x 12"    24" x 48"     40" x 72"
    12" x 12"    24" x 60"     40" x 84"
    12" x 16"    24" x 72"     40" x 96"
    12" x 24"    30" x 30"     42" x 42"
    12" x 36"    30" x 36"     42" x 48"
    12" x 48"    30" x 48"     42" x 60"
    16" x 16"    30" x 60"     42" x 72"
    16" x 24"    30" x 72"     42" x 84"
    16" x 36"    36" x 36"     42" x 96"
    16" x 48"    36" x 42"     48" x 48"
    18" x 18"    36" x 48"     48" x 60"
    18" x 24"    36" x 60"     48" x 72"
    18" x 30"    36" x 72"     48" x 84"
    18" x 36"    36" x 84"     48" x 96"
    18" x 48"    36" x 96"     
(circles or discs also available)
  • X-Ray lead glass is not tempered or fire rated
  • Maximum size available in single pane is 48" x 96"

New Ray-Bar X-Ray Protective Glass Products

  • Ray-Bar Specialty dual shielding glass for X-Ray gamma/laser, X-Ray gamma/infrared and X-Ray gamma/ultraviolet radiation protection also available.
  • Ray-Bar Special laminated lead glass products available, please contact us for special requirements and custom designs.
  • Ray-Bar X-Ray Safety Glass impact resistant lead glass meets ANSI Z97.1 and CPSC 16 CFR 1201 Cat. II
  • Ray-Bar high security X-Ray lead glass also available upon request.
  • Ray-Bar Curved or bent X-Ray lead glass products available to customers specified radiuses .

Lead Acrylic/Clear Pb Lead Plastic

Technical Data Of Clear Pb Lead Plastic (Acrylic)
Lead acrylic is made from an acrylic copolymer resin into which lead is chemically introduced as an organolead salt compound. Lead acrylic contains 30% lead weight and has a constant density of 1.6 gm/cm. Lead acrylic has a Refractive Index of 1.54 Lead equivalencies, thickness' and densities of lead acrylic are summarized below.

Lead Equiv.                   Thickness         Weight

(min)   (in)     (lb/ft)  (mm)  (in)        (lb./ft)

0.30    .0118"    <1#       7     1/4"          2.3
0.50    .0156"    1#        12     1/2"          3.9
0.80    .0312"    2#        18     3/4"          5.9
1.00    .0391"    2.5#    22     7/8"          7.2
1.50    .0625"    4#        35     1-3/8"    11.5
2.00    .0781"    5#        46     1-3/4"    13.7


Standard 


Sizes 


Available

12" X 12" 24" X 36" 48" X 48"
12" X 24" 24" X 48" 48" X 60"
18" X 24" 36" X 48" 48" X 72"
18" X 48" 36" X 60" 48" X 84"
24" X 24" 36" X 72" 48" X 96"
24" X 30" 36" X 84"

Standard sizes available from 12" X 12" UP TO 48" X 96" some thickness' are limited to certain sizes.
Lead-Acrylic modular control barriers also available

URL: http://www.raybar.com/

3-Part CSI specifications for X-Ray Protective Lead Glass For Radiation Shielding
Description Format Size Download
  • General X-Ray Specifications
    Section 13090, X-Ray Protection
  • Ray-Bar Lead Backed Drywall Specifications
    Section 09250 Gypsum Board
  • Ray-Bar Lead Lined Wood Door Specifications
    Section 08200 Wood and Plastic Doors
  • Ray-Bar Lead Lined Hollow Metal Door Specifications
    Section 08100 Metal Doors
  • Ray-Bar Neutron Shielded Door Specifications
    Section 08300 Specialty Doors
  • Ray-Bar Industrial Type Lead Lined Door Specifications
    Section 08300 Specialty Doors
  • Ray-Bar Engineering Lead Sheet
    Stock Thickness, Weights & Sizes
  • Shielding Information
    Diagnostic radiation shielding considerations
COM/ 1 kB Download

Request for Information / Request a Catalog from Ray-Bar Engineering Corporation about X-Ray Protective Lead Glass For Radiation Shielding
 
(Please check companies and/or products above.)
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     


08 56 49 - Radiation Shielding Windows
08580 - Special Function Window





Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com – Product presentation: information, news and documentation about X-Ray Protective Lead Glass For Radiation Shielding.