| Search |
|
|
|
| |
| Site Navigation |
|
|
|
| News / Publications |
|
|
|
| Jobs | |
|
|
| Service |
|
|
|
|
|


|
| |
|
| |
JOMY Inc. Safety Ladder Specification Page - 1. CSI 3-Part Specifications.
JOMY SAFETY LADDER SPECIFICATION
GUIDE
This section is based on products distributed by JOMY Safety
Products, Inc., at the following address:
6255 Longbow Drive
Boulder, CO 80301
Telephone:(303) 527-2700
(800) 255-2591
Fax: (303) 527-2800
The JOMY Safety Ladder is intended for emergency exit or rescue or
for mechanical equipment access. Looking like an ordinary drainpipe when closed, a quarter
turn of a handle deploys a 2-foot-wide industrial strength ladder with slip-resistant
rungs and a safety rail. A JOMY balcony is available to supplement access to the ladder
where required.
PART 1. GENERAL
1.1. SECTION INCLUDES
| A. |
Retractable exit ladders for use as
supplemental escape devices. |
| B. |
Retractable ladder devices to provide access
to mechanical equipment. |
1.2 REFERENCES
| A. |
Evaluation Reports; Building Officials and Code
Administrators International, Inc. (BOCA). |
| B. |
Evaluation Reports; International Conference of
Building Officals (ICBO). |
| C. |
Uniform Building Code; International Conference of
Building Officials (ICBO). |
| D. |
Uniform Fire Code; International Conference of Building
Officials (ICBO). |
| E. |
Uniform Mechanical Code; International Conference of
Building Officials (ICBO). |
| F. |
Uniform Building Code Standards; International
Conference of Building Officials (ICBO). |
| G. |
Underwriters Laboratories Inc. (UL). |
1.3 SUBMITTALS
| A. |
Submit under provisions of Section 01300. |
| B. |
Product Data: Provide manu-facturers standard
details and catalog data demonstrating compliance with referenced standards. Provide
installation instructions. |
| C. |
Shop Drawings: Submit drawings showing overall height
of ladders, and location of deployment handles in relation to floor elevations, window
sills and railings. |
| D. |
Warranty: Submit manufacturers standard warranty |
1.4 DELIVERY, STORAGE, HANDLING
| A. Store
products indoors and protect from moisture, construction traffic, and damage. |
1.5 WARRANTY
| A. |
Manufacturers standard warranty against defects
in materials and workmanship; 10 year period. |
PART 2. PRODUCTS
2.1 MANUFACTURER
| A. |
Provide products fabricated by JOMY Safety Products,
Inc., 6255 Longbow Drive, Boulder, CO 80301.
Telephone: (303) 527-2700
(800) 255-2591
Fax: (303) 527-2800 |
2.2 MATERIALS
| A. |
Stiles: Extruded Aluminum, 6063-T6 alloy. |
| B. |
Rungs: Extruded aluminum, 6005-T5 alloy and 6005-T6
alloy. |
| C. |
Brackets: 6063-T6 aluminum alloy. |
| D. |
Pivot pins, Springs, Masonry Bolts, Fasteners
and Base Plate: Stainless Steel |
2.3 LADDERS
| A. |
General:
| 1. |
Retractable ladder with deployment handles at each
point of access; stainless steel counterbalance springs; requiring less than five pounds
of force to deploy. |
| 2. |
Maintenance-free, aluminum and stainless steel
construction. |
| 3. |
Support 1,000 lbs. per rung individually; 200 lbs per 6
feet of length simultaneously. |
| 4. |
Ground support of gravity loads; building wall support
for lateral stability. Provide deployment handle at each desired access level. |
| 5. |
Provide deployment handle at each
desired access level. |
|
| B. |
Certifications
| 1. |
Exit ladder device: UBC Std. 33-3. |
| 2. |
Supplementary means of egress: Underwriters
Laboratories. |
| 3. |
Supplemental escape device: Accepted under BOCA and
ICBO evaluation reports for use up to 30 feet under appendices of Uniform Building Code
and Uniform Fire Code. |
| 4. |
Mechanical Equipment Ladder: Accepted under ICBO
evaluation reports in compliance with Uniform Mechanical Code. |
|
| C. |
Provide dual safety rails at ladders with access from
both sides. |
| D. |
Provide reinforcement channel where ladders extend
beyond wall support, such as at parapets and roof tops, or where ladder spans open areas
in excess of 7 feet between attachment points. |
| E. |
Shop fabricate and assemble to maximum extent
practicable for installation on-site with minimal labor. |
2.4. ACCESSORIES
| A. |
Provide brackets, spacers, etc., necessary for a
complete installation. |
| B. |
Provide removable deployment handle at lower
access point; provide locking hub and padlock. |
| C. |
Contractor to provide fasteners for securement
to wood construction: Stainless steel lag bolts; 3/8-inch diameter, 4-inch minimum
embedment. |
| D. |
Contractor to provide fasteners for securement to steel
construction: Stainless steel bolts, nuts, and washers; 3/8-inch diameter. |
2.5 FINISHES
| A. |
Aluminum: Clear anodized. |
| B. |
Manufacturers standard shop-applied
enamel.
| 1. |
Color: As selected from manufacturers
standards. |
| 2. |
Color: Match paint sample supplied by architect. |
|
PART 3. EXECUTION
3.1 EXAMINATION
| A. |
Verify that wall surfaces to receive units are complete
and approved prior to installing work of this section. |
3.2 INSTALLATION
| A. |
Install components in strict compliance with
manufacturers instructions. |
3.3 ADJUST AND CLEAN
| A. |
Remove debris; leave project site in
clean and orderly condition. |
Products: Jomy Safety Ladder Product Specs
Copyright © 19962009 AECinfo.com
|
|